DM240XR High-Speed Digital Modulator SNMP
MN-DM240XRRevision 13 8–3
::= { radSNMPModNVStatus 3 }
radDataRate OBJECT-TYPE
SYNTAX INTEGER (0..238000000)
ACCESS read-write
STATUS current
DESCRIPTION
"Selects the data rate in bps. Note: Changing data rate
will affect symbol rate, see comment at the end of
mibtext."
::= { radSNMPModNVStatus 4 }
radSymbolRate OBJECT-TYPE
SYNTAX INTEGER (0..68000000)
ACCESS read-write
STATUS current
DESCRIPTION
"Selects the symbol rate in sps."
::= { radSNMPModNVStatus 5 }
radSymbolRateMode OBJECT-TYPE
SYNTAX INTEGER {
variable(0),
fixed(1)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Selects symbol rate mode. This can only be modified if
the factory configuration is set to both variable and
fixed.
This is obsolete."
::= { radSNMPModNVStatus 6 }
radStrapCode OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS optional
DESCRIPTION
"The strap code is a quick set key that sets many modem
parameters.
Not implemented."
::= { radSNMPModNVStatus 7 }
radConvolutionalEncoder OBJECT-TYPE
SYNTAX INTEGER {
none(0),
ifecRate1x2(1),
ifecRate2x3(2),
ifecRate3x4(3),
ifecRate5x6(4),
ifecRate7x8(5),
ifecRate6x7(6),
ifecRate4x5(7),
ifecRate8x9(8),
ifecRate9x10(9),
ifecRate1x4(128),
ifecRate1x3(129),
ifecRate2x5(130),
ifecRate3x5(131)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Selects Tx code rate and type.
Note: Changing the convolutional encoder will affect
symbol rate and data rate. See note at the end of this
section. Unsupported choices include:
none
viterbi6x7
"
::= { radSNMPModNVStatus 8 }