DM240XR High-Speed Digital Modulator SNMP
MN-DM240XRRevision 13 8–9
ACCESS read-write
STATUS current
DESCRIPTION
"Selects the source of clock output from the Terrestrial
Interface. See the Clock Source Selection Matrix."
::= { radSNMPModNVStatus 34 }
radLastRateControl OBJECT-TYPE
SYNTAX INTEGER {
symbol(0),
data(1),
auto(2)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Allows the modulator to behave with symbol rate or data
rate precedence based on the selection.
See rate control notes."
::= { radSNMPModNVStatus 35 }
radClearLatchedAlarms OBJECT-TYPE
SYNTAX INTEGER {
clearAlarms(1)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Clears all latched alarms."
::= { radSNMPModNVStatus 36 }
radPcrRestamping OBJECT-TYPE
SYNTAX INTEGER {
off(0),
on(1)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Enables the PCR restamping in AASI."
::= { radSNMPModNVStatus 37 }
radMultiPiicMode OBJECT-TYPE
SYNTAX INTEGER {
manual(1),
redundancy(2)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Selects the Multi-PIIC mode."
::= { radSNMPModNVStatus 38 }
radRedundancyMode OBJECT-TYPE
SYNTAX INTEGER {
forcePrime(0),
forceBackup(1),
manualRevert(2),
autoRevert(3)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Selects the Redundancy submode if the Multi-PIIC mode
is redundancy."
::= { radSNMPModNVStatus 39 }
radPrimePiicSlot OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
"If the Multi-PIIC mode is manual, radPrimePiicSlot
selects the input slot.