QAM256 Digital Video Modulator and Upconverter SNMP MIB
TM077 – Rev. 4.0 B-5
SYNTAX INTEGER { symbol(1), data(2), auto(3) }
ACCESS read-write
STATUS current
DESCRIPTION
"Selects rate control mode."
::= { radQAM256ModNVStatus 25 }
radQAM256TxChannelTable OBJECT-TYPE
SYNTAX INTEGER { useiastd(1), useiahrc(2), useiairc(3), ustradstd(4),
ustradhrc(5), ustradirc(6) }
ACCESS read-write
STATUS current
DESCRIPTION
"Valid for QAM256Cable Modulator Only. Not limited to the above listed tables."
::= { radQAM256ModNVStatus 26 }
radQAM256TxChannelEntry OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-write
STATUS current
DESCRIPTION
"This corresponds to the index entry into a selected
channel table. Maximum entry for EIA tables is 116 where as that for TRAD tables is 67. Valid for QAM256 Cable
Modulator Only."
::= { radQAM256ModNVStatus 27 }
-- QAM256 modulator status information.
radQAM256TxMajorAlarm1Status OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS current
DESCRIPTION
"A bit field. On startup, the agent initializes this to the value '00000000'B
Bit 0=Mod Hardware fault
Bit 1=Tx Synthesizer fault
Bit 2=Tx Data PLL lock fault
Bit 3=Tx Framing Lock (Unused)
Bit 4=Mod Chip 1 Lock fault (Unused)
Bit 5=Mod Chip 2 Lock fault (Unused)
Bit 6=Mod Chip 3 Lock fault (Current chip used)
Bit 7=Spare
0 = Pass, 1 = Fail"
::= { radQAM256ModStatus 1 }
radQAM256TxMajorAlarm2Status OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS current
DESCRIPTION
"A bit field. On startup, the agent initializes this to the value '00000000'B
Bits 0 ..7 Spares
0 = Pass, 1 = Fail"
::= { radQAM256ModStatus 2 }
radQAM256TxMinorAlarm1Status OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS current
DESCRIPTION
"A bit field. On startup, the agent initializes this to the value '00000000'B
Bit 0=Clock activity detect fault
Bit 1=Data activity detect fault
Bit 2..7=Spares"
::= { radQAM256ModStatus 3 }